Three ways back, lightest first

Most problems touch one part of the app, so most fixes touch one part too.

  1. 1. Roll back one module

    Every module, such as CRM, Finance or Documents, has its own version. If one breaks, it goes back to its last good version in seconds. Nothing else restarts, and no server is switched. This handles most failures.

  2. 2. Turn a feature off

    A feature flag hides the broken part while the fix goes in. Your plan, your data and the rest of the app stay as they are.

  3. 3. Switch to the standby server

    Only for the rare big failure: the core of the app, or our UK server or its network, going down. A standby server in Amsterdam holds a live copy of the data and runs exactly the versions production runs, so the switch takes seconds.

How it works in more detail

Staging and standby are kept apart

New, untested versions run on staging. The standby always runs exactly what production runs, against the live copy of the data. So a switch never puts untested code or a mismatched database in front of you. Staging only reaches production through a normal release.

AI on call, around the clock, with a person in charge

An AI on-call agent watches health checks, error rates and logs for every module. When something fails, it picks the lightest fix from the list above and applies it within limits we set. It opens the incident, writes down what it found and what it did, and pages a person. It then checks the fix on staging and confirms production is healthy again.

Anything outside those limits waits for a person: changes to data, a switch inside a client's own environment, or anything that costs money.

A status page that tells the truth

status.lucasia.ai (opens in a new tab) shows the live state of each system, the measured uptime, and every incident with its real cost, for example: "Documents was 2 seconds slower while it moved to the standby server. Cause found, fix testing, no data lost." If something is down, the page says so. Days before we started measuring show gray, never green.

We think being open about minor problems is what makes an uptime number believable.

What we promise

99.5% monthly uptime for the Lucasia app, with service credits as set out in our Service Level Summary. That is at most about 3 hours 36 minutes of downtime in a 30 day month, not counting announced maintenance.

We will only promise 99.99% once the standby switch has passed our failover drills and the status page shows three full months measured at that level. Until then, we do not claim it.

Where we are today

  • The status page is live, and its measurements started on 25 October 2026.
  • The standby server in Amsterdam is being set up. It counts toward our promise only after the failover drills are done.
  • The AI on-call agent is being built. Until it is in place, the status checks alert a person directly.

We update this list as each part goes live. Questions? Email hello@lucasia.ai.